Effluent Decontamination Veterinary Clinic Equipment Bulk Steam Sterilization For Animal Labs

Brand Name : Medpharm

Model Number : MD-0.6V

Certification : CE/SGS

Place of Origin : China

MOQ : 1 pc

Price : Negotiation

Payment Terms : T/T in advance, LC AT SIGHT

Supply Ability : 10 pcs per month

Delivery Time : 30 working days after received your payment

Packaging Details : Solid plywood case suitable for long distance transportation

Model Name : MD-0.6V veterinary autoclave

Capacity : 600L

Inner chamber : 600*600*1670mm

Outer dimension : 1200*2000*2010mm

Sterilization temperature : 105 to 134 degree

Sterilization auxiliary : Sterilization trays or baskets

Chamber material : 304 or 316L

Door type : Single or double vertical sliding door

Contact Now

Effluent Decontamination Veterinary Autoclave Bulk Steam Sterilization For Animal Labs


Specification

Model

Chamber Size

Overall Size

Net Weight

Steam

Water

Power

W*H*D mm

W*H*D mm

Kg

Kg/cycle

Kg/cycle

KVA

MD-0.11V

400*400*700

1000*1800*1040

650

14

15

2

MD-0.16V

400*400*1000

1000*1800*1340

700

16

20

2

MD-0.20V

400*400*1300

1000*1800*1640

750

18

25

2

MD-0.24V

600*600*670

1200*2000*1010

800

20

30

2

MD-0.30V

600*600*840

1200*2000*1180

850

22

35

2

MD-0.36V

600*600*1000

1200*2000*1340

900

25

40

2

MD-0.45V

600*600*1250

1200*2000*1590

980

27

50

2

MD-0.60V

600*600*1670

1200*2000*2010

1100

30

60

3


Program Parameter

Cycle name

Further details

Application

Instruments/Tools

3 times Vacuum, expose temperature 132℃, expose time 8 min, drying time 5 min.

Solid materials to be sterilized:
●Packaged instruments
●Empty glass containers
●Empty metal containers
Porous materials to be sterilized:
●Rubber articles

Clothing

3 times Vacuum, expose temperature 121℃, expose time 15 min, drying time 25 min.

Materials to be sterilized from which air can’t be easily displaced
●Textile

User Programmable

All preset parameters can be reset; Multiple customized programs can be set and stored by user.

Customized

Test programs

B-D Test

3 times Vacuum, expose temperature 134℃, expose time 4 min, drying time 3 min.

Test program

Vacuum Leak Test

Test the chamber connecting parts’ tightness effect. It’s important to ensure the sterilization effect.

Test program





















Features

  • Piping, fittings, and valves are available in stainless steel.
  • All parts and components subject to repair are publicly available (i.e. non-proprietary) from open market sources, including controls, valves and fittings.
  • Safety relief valves and drains are integral to the plumbing configuration.
  • Baffled steam inlets minimize direct condensate on the load, reduce load wetting, and help
  • assure proper steam uniformity within the chamber.
  • Cabinet insulation retains heat and minimizes heat loss to the room. The sterilizer jacket and all steam service piping include a minimum 1" mineral wool-based insulation.
  • An integral waste water cooling function reduces discharge temperature to the Drain to less than 140°F (60°C).
  • On units equipped with steam generators, an pressure switch is included to back up the safety relief valve by automatically shutting down the steam generator if an over pressure condition exists.
  • Easy-to-read pressure gauges ensure simple and safe operation.
  • Other components required for the intended application may include a steam generator, vacuum pump, water ejector, etc. depending on the options chosen.

Description

Feature of the veterinary autoclave is the control of the sterilization phase according to a pressure signal, rather than temperature. Obviously, the temperature readout varies as a function of the position of the sensor, whilst the pressure is uniform throughout the chamber.

However, process control is performed by reading in the chamber (and from inside the product) temperature signals whose match with the pressure value, as constantly verified by the controller, demonstrates that the autoclave is operating correctly.

This principle, in saturated-steam conditions (when there is a two-way T/P correspondence) allows to obtain uniformities in sterilization temperature which are far better than the currently required level of ±1.0 °C.

Applications

  • Un-Wrapped Goods
  • Wrapped Goods
  • Small volumes of Liquids
  • Rubbers and alumium caps


Competitive Advantage

Effluent Decontamination.
Available on gravity and pre-vacuum units. Retains liquid effluent, if any, within the chamber for the duration of the sterilization cycle. Aerosol effluent passes through a 0.2 micron hydrophobic HEPA filter with >99.999% efficiency; the filter is located within the chamber and is sterilized in situ to eliminate the need for disposal after each cycle. The filter is easily replaced by the user when required without special tools or service personnel.

Effluent Decontamination Veterinary Clinic Equipment Bulk Steam Sterilization For Animal Labs


Product Tags:

Veterinary Medical Equipment

      

Veterinary Clinic Equipment

      
Buy cheap Effluent Decontamination Veterinary Clinic Equipment Bulk Steam Sterilization For Animal Labs product

Effluent Decontamination Veterinary Clinic Equipment Bulk Steam Sterilization For Animal Labs Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: ZHANGJIAGANG MEDPHARM MACHINERY LTD.
*Subject:
*Message:
Characters Remaining: (0/3000)